SinceVision Adds Wide-Spot Laser Sensor for Rough-Surface Measurement

The SGI-N030W uses an expanded laser spot and dual-sensor synchronisation to target stable micrometre-level measurement in battery, semiconductor and precision-assembly work.

SinceVision has introduced the SGI-N030W, a wide-spot laser displacement sensor aimed at high-speed, non-contact dimensional measurement on rough, textured and irregular surfaces. The product extends the company’s SGI Series and is intended for lithium-ion battery manufacturing, semiconductor processing and precision mechanical engineering, where micrometre-level measurement is required.

The design addresses a common problem with conventional point-spot laser sensors. Because these devices concentrate reflected laser energy on a small area, microscopic scratches, grain boundaries, brushed textures and matte finishes can produce signal changes that are interpreted as dimensional shifts. That can lead to false defect warnings and additional inspection. The SGI-N030W instead uses an expanded spot and optical triangulation, collecting reflected light over a wider area so that local microscopic peaks and valleys are averaged before signal conversion. SinceVision says this reduces the influence of surface roughness and optical scattering on materials such as drawn metals, sandblasted surfaces and coated battery foils.

Specifications and interfacing

The sensor has a 30 mm reference distance and a ±5 mm measurement range. SinceVision specifies 0.05 µm repeatability on a diffuse white target under static conditions and ±0.02% of full-scale linearity across the range. A 50 kHz sampling frequency, equal to a 20 µs update interval, is intended to support high-speed measurement and monitoring of dynamic processes. Communication options include RS485, 100Base-TX Ethernet and switchable analogue outputs for 4–20 mA current or 0–10 V voltage signals. Master-slave synchronisation allows two sensors to operate in opposition, measuring from either side of a component or moving material.

Battery electrode thickness

One focus is in-line thickness measurement of lithium-ion battery electrodes, where coating thickness and uniformity affect energy density, internal resistance and long-term cell stability. SinceVision notes that offline checks with contact micrometers or drop indicators can introduce operator variability and may deform wet or uncured electrode material. Periodic spot measurements also cannot provide continuous coverage across a production reel.

The proposed arrangement uses two synchronised sensors above and below a moving electrode web. Mounted on a calibrated, low-thermal-expansion marble gantry, the opposing heads measure their respective clearances to the material; a controller combines these readings with the fixed mounting datum to calculate absolute thickness in real time. SinceVision reports that production trials demonstrated stable, repeatable measurement within ±0.3 µm at a web speed of 300 mm/s. The 50 kHz sampling rate is intended to provide longitudinal resolution for detecting local coating agglomerations, edge thinning and exposed substrate before winding.

Other target applications

For semiconductor manufacturing, the non-contact method is aimed at sensitive wafer surfaces. Potential uses include wafer position verification, edge detection, height measurement and checks of wafer seating and chuck alignment in atmospheric transfer modules and vacuum load-lock systems. In precision assembly, the sensor can monitor voice coil motors, linear actuators and micro-steppers. Its sampling rate is intended to capture transient displacement, mechanical oscillation, settling behaviour and end-stop overshoot across the measurement range, with position data sent to machine controls through Ethernet for real-time monitoring.

Surface-error challenge

Jack Li, global sales and marketing director at SinceVision, says false defect warnings caused by surface texture remain a recurring challenge in battery manufacturing and precision assembly. He explains that conventional point-beam laser sensors can interpret microscopic scratches and rough coatings as actual thickness variations, slowing production lines and creating extra manual inspection work. The SGI-N030W’s wider optical spot is designed to average out such surface-related variation, while opposing sensor heads are synchronised for high-speed thickness verification.

NB

Nadia Belmonte

Nadia Belmonte covers analytical laboratory instruments and weighing systems, including HPLC, spectrophotometers, pH meters, analytical balances, and checkweighers. Her evidence reviews detection limits, repeatability, weighing intervals, sample preparation effects, and calibration uncertainty against stated method requirements, while checking applicable standards such as ISO/IEC 17025 for laboratory competence and OIML R 76 for non-automatic weighing instruments. She helps laboratory managers, quality engineers, and procurement teams evaluate instrument suitability, maintenance needs, and lifecycle cost without treating any single specification as a universal guarantee.